Elektrik Elektronik Mühendisliği Bölümü Yayın Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/411

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 6
    Citation - Scopus: 6
    Mitigation of Atmospheric Turbulence on Up and Downlink Optical Communication Systems Using Receiver Diversity and Adaptive Optics
    (Springer, 2022) Gokce, Muhsin Caner; Baykal, Yahya; Ata, Yalcin
    Improvement in the performance of uplink and downlink optical communication systems by means of receive diversity and adaptive optics correction is investigated. We develop a communication system model using adaptive optics correction in the transmitter and maximum ratio combining diversity technique in the receiver. The effect of adaptive optics correction modes, receive diversity, zenith angle, link length, wind speed and the height of transmitter/receiver on the ground are evaluated. Performance improvement is observed with both adaptive optics correction and the receive diversity. It is aimed to provide researchers an option to determine the method they will use to reduce the effect of turbulence. As the numerical values of the main results, we report that adaptive optics correction with 5 mode Zernike removal reduces BER from 10(-8) to 10(-10) for one receiver. When the number of receivers is 6, BER is found to reduce from 10(-6) to 10(-12). The results obtained in this study can be beneficial to optimize the design of the slant path uplink and downlink optical communication links between the ground and low-orbit satellites that are exposed to atmospheric turbulence.
  • Article
    Citation - WoS: 22
    Citation - Scopus: 19
    Laser Array Beam Propagation Through Liver Tissue
    (Springer, 2020) Baykal, Yahya; Ata, Yalcin; Gokce, Muhsin Caner
    Laser array beam propagating through mouse liver tissue is investigated. The turbulence power spectrum of the liver tissue is employed in the extended Huygens-Fresnel method to obtain an optical intensity profile and beam broadening at the observation point in biological liver tissue. Variations of the beam profile and the beam broadening are simulated based on the number of beamlets, source size, wavelength and the ring radius of the array. A biological tissue, illuminated by the laser array beam, exhibits different beam profiles and beam spot radius variations when the number of beamlets, source size, wavelength and the ring radius of the laser array beam are varied. Examining these variations observed in the propagated optical beam and comparing them with the test cases, abnormalities such as cancer and tumor in a biological liver tissue can be diagnosed.