Matematik Bölümü Yayın Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/413
Browse
40 results
Search Results
Article Citation - WoS: 16Citation - Scopus: 16Comparative Application of Wavelet Approaches To Absorption and Ratio Spectra for the Simultaneous Determination of Diminazene Aceturate and Phenazone in Veterinary Granules for Injection(Govi-verlag Pharmazeutischer verlag Gmbh, 2005) Dinç, E; Baleanu, Dumitru; Kanbur, M; Baleanu, D; MatematikA comparison of two wavelet approaches, Daubechies and reverse Biorthogonal, is described for the quantitative resolution of a binary mixture of diminazene aceturate (DIMA) and phenazone (PHE) in veterinary granules for injection without any chemical separation. These two approaches were specified as db4 (a = 180) and rbior3.7 (a = 125) respectively, after testing the signal analysis parameters for the overlapping absorption spectra and ratio spectra. In the first step db4 (a = 180) was applied to the original absorbance data vector of DIMA and PHE. In the second step rbio3.7 (a = 125) was applied to the ratio spectra data vectors of DIMA using the divisor PHE. The same approach was also subjected to the ratio spectra of PHE using the divisor DIMA. The db4 (a = 180) and rbior3.7 (a = 125) calibration graphs were constructed using the transformation values obtained in the wavelet domain. In the method validation, the wavelet calibration functions were tested using synthetic mixtures and the standard addition technique. The simultaneous quantitative analysis of DIMA and PHE in the commercial veterinary preparation was achieved by the elaborated methods. The assay results were compared with each other and good agreement was observed.Article Citation - WoS: 13Citation - Scopus: 14Continuous Wavelet Transformation Applied To the Simultaneous Quantitative Analysis of Two-Component Mixtures(Govi-verlag Pharmazeutischer verlag Gmbh, 2004) Dinç, E; Baleanu, Dumitru; Baleanu, D; Üstündag, Ö; Aboul-Enein, HY; MatematikIn this paper we developed a graphical method based on Haar (HA) and Mexican (MEX) one-dimensional continuous wavelet transforms and we applied it to a mixture of hydrochlorothiazide (HCT) and spironolactone (SP) in the presence of strongly overlapping signals. Keeping in mind to obtain an appropriately transformed spectrum, we tested several values of the scaling parameter a and the point number of the analysed spectrum in the concentration range of 2-22 mug/ml for both active compounds. The optimal values of the scale parameters and the corresponding frequencies were found to be a = 32 and 0.031 for HA and a = 30 and 0.008 for MEX corresponding to 400 points. HA and MEX methods based on a zero crossing technique were applied to the analysed signal and their regression lines at the selected points were obtained. The validation of the above methods was carried out by analysing different synthetic mixtures containing HCT and SP. MATLAB 6.5. Software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were briefly explained. The method developed in this paper is rapid, easy to apply, inexpensive and is suitable for analysing the overlapping signals of compounds in their mixtures without any chemical pre-treatment.Article Citation - WoS: 8Citation - Scopus: 8Continuous Wavelet Transform Applied To the Quantitative Analysis of a Binary Mixture(Revista Chimie Srl, 2009) Dinc, Erdal; Baleanu, Dumitru; Baleanu, Dumitru; Üstündag, Ö; Aboul-Enein, HY; MatematikSignal processing methods, continuous wavelet transform (CWT) methods, were proposed for the simultaneous spectral determination of ampicillin sodium (AS) and sulbactam sodium (SS) in their synthetic binary mixtures and pharmaceutical preparations. Firstly, the ratio spectra were obtained by dividing the absorption spectra of a pure compound and its binary mixture by a standard spectrum of one of the compounds in binary mixture. Secondly, the ratio spectra of AS, SS and their samples were processed by the Mexican hat-CWT and Symtles3-CWT (MEX-CWT and SYM3-CWT, respectively). hi this application, the MEX and SYM3 among wavelet families were found to be optimal to obtain the highest spectral recoveries. Calibration graphs of AS and SS in the linear concentration range of 10-70 mu g/mL and 10-55 mu g/mL were obtained by measuring the amplitudes of the transformed ratio signals, respectively. Percent mean recoveries obtained by application of the CWT methods to the synthetic mixtures were found between 99.1 % and 103.6 %. Both SYM3-CWT and MEX-CWT methods were applied to the real samples containing two active compounds and successful results were obtained.Article -Simultaneous chemometric determination of pyridoxine hydrochloride and isoniazid in tablets bymultivariate regression methods(Wiley-Blackwell, 2010) Dinç, Erdal; Üstündağ, Ögür; Baleanu, DumitruThe sole use of pyridoxine hydrochloride during treatment of tuberculosis gives rise to pyridoxine deficiency. Therefore, a combination of pyridoxine hydrochloride and isoniazid is used in pharmaceutical dosage form in tuberculosis treatment to reduce this side effect. In this study, two chemometric methods, partial least squares (PLS) and principal component regression (PCR), were applied to the simultaneous determination of pyridoxine (PYR) and isoniazid (ISO) in their tablets. A concentration training set comprising binary mixtures of PYR and ISO consisting of 20 different combinations were randomly prepared in 0.1 M HCl. Both multivariate calibration models were constructed using the relationships between the concentration data set (concentration data matrix) and absorbance data matrix in the spectral region 200-330 nm. The accuracy and the precision of the proposed chemometric methods were validated by analyzing synthetic mixtures containing the investigated drugs. The recovery results obtained by applying PCR and PLS calibrations to the artificial mixtures were found between 100.0 and 100.7%. Satisfactory results obtained by applying the PLS and PCR methods to both artificial and commercial samples were obtained. The results obtained in this manuscript strongly encourage us to use them for the quality control and the routine analysis of the marketing tablets containing PYR and ISO drugs. CopyrightArticle Citation - WoS: 21Citation - Scopus: 39The Development of Sustainable Iot E-Waste Management Guideline for Households(Pergamon-elsevier Science Ltd, 2022) Savita, K. S.; Kalid, Khairul Shafee; Ahmad, Mohammad Nazir; Zaffar, Maryam; Rahim, Eidia Erriany Abdul; Ahmadian, Ali; Razip, Marym Mohamad; Abdul Rahim, Eidia ErrianyThe introduction of new technology, such as the Internet of Things (IoT), entails a growth in digital devices, which could ultimately result in a high amount of electronic trash (e-waste) production if they are not appropriately managed. Apart from that, the regulation on possible "IoT E-waste" generation is yet to be regulated, probably due to the new development and implementation of IoT globally. Hence, this paper proposed a Sustainable IoT E-waste Management guideline for households. This guideline could assist government agencies and policymakers in their strategies, planning, development, and implementation of a sustainable household IoT e-waste management initiatives in Malaysia. This study is an exploratory study that adopts a qualitative case study research method. The guideline was developed based on the Integrated Sustainable Waste Management (ISWM) Model. This guideline contributes to Malaysia's sustainability agenda in reducing carbon emissions intensity towards 2030 by 45 percent.Article Citation - WoS: 49Citation - Scopus: 51Multidetermination of Thiamine Hcl and Pyridoxine Hcl in Their Mixture Using Continuous Daubechies and Biorthogonal Wavelet Analysis(Elsevier Science Bv, 2003) Baleanu, D; Dinç, EA new graphical method based on the one-dimensional wavelet transform (WT) was proposed and tested on mixture of thiamine hydrochloride (THI) and pyridoxine hydrochloride (PYR) in the presence of strongly overlapping signals. We selected from the data of the UV-VIS absorption spectra a signal consisting of 1150 points corresponding to the concentration range 8-32 mg ml(-1) for each vitamin and we subjected it to Daubechies8 (DAUB8) and Biorthogonal6.8 (BIOR6.8) wavelet transforms. Since the peaks of the transformed signals were bigger than original ones a zero crossing method was applied to obtain the calibration graphs. In addition, the validity of Beer-Lambert law was assumed for the transformed signals. An appropriate scale setting was choosing to obtain an alternative calibration for each method. MATLAB 6.5 software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were given. The obtained results were successfully compared among each other as well as with those obtained by other literature methods. The method developed in this paper is rapid, easy to apply, not expensive and it is suitable for analyzing of the overlapping signals of compounds in their mixtures without any chemical pre-treatment. (C) 2002 Elsevier Science B.V. All rights reserved.Article Citation - WoS: 2Existence of Measure Pseudo-Almost Automorphic Functions and Applications To Impulsive Integro-Differential Equation(Aip Publishing, 2021) Baleanu, Dumitru; George, Soumya; Grayna, J.; Kavitha, V.This article's main objective is to establish the measure pseudo-almost automorphic solution of an integro-differential equation with impulses. We develop the existence results based on the Banach contraction principle mapping and Krasnoselskii and Krasnoselskii-Schaefer type fixed point theorems. Finally, some examples are given to illustrate the significance of our theoretical findings.Published under an exclusive license by AIP PublishingArticle Citation - WoS: 37Citation - Scopus: 40Design of a Fractional-Order Atmospheric Model Via a Class of Act-Like Chaotic System and Its Sliding Mode Chaos Control(Aip Publishing, 2023) Baishya, Chandrali; Veeresha, Pundikala; Baleanu, Dumitru; Naik, Manisha KrishnaInvestigation of the dynamical behavior related to environmental phenomena has received much attention across a variety of scientific domains. One such phenomenon is global warming. The main causes of global warming, which has detrimental effects on our ecosystem, are mainly excess greenhouse gases and temperature. Looking at the significance of this climatic event, in this study, we have connected the ACT-like model to three climatic components, namely, permafrost thaw, temperature, and greenhouse gases in the form of a Caputo fractional differential equation, and analyzed their dynamics. The theoretical aspects, such as the existence and uniqueness of the obtained solution, are examined. We have derived two different sliding mode controllers to control chaos in this fractional-order system. The influences of these controllers are analyzed in the presence of uncertainties and external disturbances. In this process, we have obtained a new controlled system of equations without and with uncertainties and external disturbances. Global stability of these new systems is also established. All the aspects are examined for commensurate and non-commensurate fractional-order derivatives. To establish that the system is chaotic, we have taken the assistance of the Lyapunov exponent and the bifurcation diagram with respect to the fractional derivative. To perform numerical simulation, we have identified certain values of the parameters where the system exhibits chaotic behavior. Then, the theoretical claims about the influence of the controller on the system are established with the help of numerical simulations.Article Multidetermination of thiamine HCl and pyridoxine HCl in their mixture using continuous daubechies and biorthogonal wavelet analysis(Elsevier, 2003) Dinç, E.; Baleanu, DumitruA new graphical method based on the one-dimensional wavelet transform (WT) was proposed and tested on mixture of thiamine hydrochloride (THI) and pyridoxine hydrochloride (PYR) in the presence of strongly overlapping signals. We selected from the data of the UV-VIS absorption spectra a signal consisting of 1150 points corresponding to the concentration range 8-32 mg ml(-1) for each vitamin and we subjected it to Daubechies8 (DAUB8) and Biorthogonal6.8 (BIOR6.8) wavelet transforms. Since the peaks of the transformed signals were bigger than original ones a zero crossing method was applied to obtain the calibration graphs. In addition, the validity of Beer-Lambert law was assumed for the transformed signals. An appropriate scale setting was choosing to obtain an alternative calibration for each method. MATLAB 6.5 software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were given. The obtained results were successfully compared among each other as well as with those obtained by other literature methods. The method developed in this paper is rapid, easy to apply, not expensive and it is suitable for analyzing of the overlapping signals of compounds in their mixtures without any chemical pre-treatment. (C) 2002 Elsevier Science B.V. All rights reserved.Article Citation - Scopus: 11Wavelet Analysis for the Multicomponent Determination in a Binary Mixture of Caffeine and Propyphenazone in Tablets(Elsevier Masson SAS, 2004) Baleanu, D.; Aboul-Enein, H.Y.; Dinç, E.An approach based on both discrete and continuous wavelet analysis followed by a zero-crossing technique was developed. We applied this approach to obtain a high resolution in the binary mixture of caffeine (CA) and propyphenazone (PR) in the presence of their overlapping signals in the working length. The optimization of the wavelet families was accomplished for this mixture. The de-noise procedure was carried out by using 4-level Haar discrete wavelet transform and the resulted de-noised signal was investigated by continuous Mexican (MEX) and Haar (HA) transforms. Finally, a zero-crossing technique was applied on the transformed signal and the constructed calibration was tested by analyzing the composition of the different mixture containing CA and PR. All calculations have been performed within EXCEL and Matlab 6.5 software. The obtained results indicate that our procedure is flexible and applicable for the mixture analysis. © 2004 Elsevier SAS. All rights reserved.
