Matematik Bölümü Yayın Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/413

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 16
    Citation - Scopus: 16
    Comparative Application of Wavelet Approaches To Absorption and Ratio Spectra for the Simultaneous Determination of Diminazene Aceturate and Phenazone in Veterinary Granules for Injection
    (Govi-verlag Pharmazeutischer verlag Gmbh, 2005) Dinç, E; Baleanu, Dumitru; Kanbur, M; Baleanu, D; Matematik
    A comparison of two wavelet approaches, Daubechies and reverse Biorthogonal, is described for the quantitative resolution of a binary mixture of diminazene aceturate (DIMA) and phenazone (PHE) in veterinary granules for injection without any chemical separation. These two approaches were specified as db4 (a = 180) and rbior3.7 (a = 125) respectively, after testing the signal analysis parameters for the overlapping absorption spectra and ratio spectra. In the first step db4 (a = 180) was applied to the original absorbance data vector of DIMA and PHE. In the second step rbio3.7 (a = 125) was applied to the ratio spectra data vectors of DIMA using the divisor PHE. The same approach was also subjected to the ratio spectra of PHE using the divisor DIMA. The db4 (a = 180) and rbior3.7 (a = 125) calibration graphs were constructed using the transformation values obtained in the wavelet domain. In the method validation, the wavelet calibration functions were tested using synthetic mixtures and the standard addition technique. The simultaneous quantitative analysis of DIMA and PHE in the commercial veterinary preparation was achieved by the elaborated methods. The assay results were compared with each other and good agreement was observed.
  • Article
    Citation - WoS: 13
    Citation - Scopus: 14
    Continuous Wavelet Transformation Applied To the Simultaneous Quantitative Analysis of Two-Component Mixtures
    (Govi-verlag Pharmazeutischer verlag Gmbh, 2004) Dinç, E; Baleanu, Dumitru; Baleanu, D; Üstündag, Ö; Aboul-Enein, HY; Matematik
    In this paper we developed a graphical method based on Haar (HA) and Mexican (MEX) one-dimensional continuous wavelet transforms and we applied it to a mixture of hydrochlorothiazide (HCT) and spironolactone (SP) in the presence of strongly overlapping signals. Keeping in mind to obtain an appropriately transformed spectrum, we tested several values of the scaling parameter a and the point number of the analysed spectrum in the concentration range of 2-22 mug/ml for both active compounds. The optimal values of the scale parameters and the corresponding frequencies were found to be a = 32 and 0.031 for HA and a = 30 and 0.008 for MEX corresponding to 400 points. HA and MEX methods based on a zero crossing technique were applied to the analysed signal and their regression lines at the selected points were obtained. The validation of the above methods was carried out by analysing different synthetic mixtures containing HCT and SP. MATLAB 6.5. Software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were briefly explained. The method developed in this paper is rapid, easy to apply, inexpensive and is suitable for analysing the overlapping signals of compounds in their mixtures without any chemical pre-treatment.