Bilgisayar Mühendisliği Bölümü Yayın Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/253
Browse
8 results
Search Results
Article Citation - WoS: 11Citation - Scopus: 12Diagnosis of Osteoarthritic Changes, Loss of Cervical Lordosis, and Disc Space Narrowing on Cervical Radiographs With Deep Learning Methods(Turkish Joint Diseases Foundation, 2022) Tokdemir, Gul; Ureten, Kemal; Atalar, Ebru; Duran, Semra; Maras, Hakan; Maras, YukselObjectives: In this study, we aimed to differentiate normal cervical graphs and graphs of diseases that cause mechanical neck pain by using deep convolutional neural networks (DCNN) technology. Materials and methods: In this retrospective study, the convolutional neural networks were used and transfer learning method was applied with the pre-trained VGG-16, VGG-19, Resnet-101, and DenseNet-201 networks. Our data set consisted of 161 normal lateral cervical radiographs and 170 lateral cervical radiographs with osteoarthritis and cervical degenerative disc disease. Results: We compared the performances of the classification models in terms of performance metrics such as accuracy,Article Citation - WoS: 43Citation - Scopus: 50Detection of Hip Osteoarthritis by Using Plain Pelvic Radiographs With Deep Learning Methods(Springer, 2020) Ureten, Kemal; Arslan, Tayfun; Gultekin, Korcan Emre; Demir, Ayse Nur Demirgoz; Ozer, Hafsa Feyza; Bilgili, YaseminObjective The incidence of osteoarthritis is gradually increasing in public due to aging and increase in obesity. Various imaging methods are used in the diagnosis of hip osteoarthritis, and plain pelvic radiography is the first preferred imaging method in the diagnosis of hip osteoarthritis. In this study, we aimed to develop a computer-aided diagnosis method that will help physicians for the diagnosis of hip osteoarthritis by interpreting plain pelvic radiographs. Materials and methods In this retrospective study, convolutional neural networks were used and transfer learning was applied with the pre-trained VGG-16 network. Our dataset consisted of 221 normal hip radiographs and 213 hip radiographs with osteoarthritis. In this study, the training of the network was performed using a total of 426 hip osteoarthritis images and a total of 442 normal pelvic images obtained by flipping the raw data set. Results Training results were evaluated with performance metrics such as accuracy, sensitivity, specificity, and precision calculated by using the confusion matrix. We achieved accuracy, sensitivity, specificity and precision results at 90.2%, 97.6%, 83.0%, and 84.7% respectively. Conclusion We achieved promising results with this computer-aided diagnosis method that we tried to develop using convolutional neural networks based on transfer learning. This method can help clinicians for the diagnosis of hip osteoarthritis while interpreting plain pelvic radiographs, also provides assistance for a second objective interpretation. It may also reduce the need for advanced imaging methods in the diagnosis of hip osteoarthritis.Article Citation - WoS: 9Citation - Scopus: 11The Diagnosis of Femoroacetabular Impingement Can Be Made on Pelvis Radiographs Using Deep Learning Methods(Turkish Joint Diseases Foundation, 2023) Atalar, Ebru; Ureten, Kemal; Kanatli, Ulunay; Ciceklidag, Murat; Kaya, Ibrahim; Vural, Abdurrahman; Maras, YukselObjectives: The aim of this study was to evaluate diagnostic ability of deep learning models, particularly convolutional neural network models used for image classification, for femoroacetabular impingement (FAI) using hip radiographs. Materials and methods: Between January 2010 and December 2020, pelvic radiographs of a total of 516 patients (270 males, 246 females; mean age: 39.1 +/- 3.8 years; range, 20 to 78 years) with hip pain were retrospectively analyzed. Based on inclusion and exclusion criteria, a total of 888 hip radiographs (308 diagnosed with FAI and 508 considered normal) were evaluated using deep learning methods. Pre-trained VGG-16, ResNet-101, MobileNetV2, and Inceptionv3 models were used for transfer learning. Results: As assessed by performance measures such as accuracy, sensitivity, specificity, precision, F-1 score, and area under the curve (AUC), the VGG-16 model outperformed other pre-trained networks in diagnosing FAI. With the pre-trained VGG-16 model, the results showed 86.6% accuracy, 82.5% sensitivity, 89.6% specificity, 85.5% precision, 83.9% F1 score, and 0.92 AUC. Conclusion: In patients with suspected FAI, pelvic radiography is the first imaging method to be applied, and deep learning methods can help in the diagnosis of this syndrome.Article Citation - WoS: 22Citation - Scopus: 25Deep Learning Methods in the Diagnosis of Sacroiliitis From Plain Pelvic Radiographs(Oxford Univ Press, 2023) Ureten, Kemal; Maras, Yuksel; Duran, Semra; Gok, KevserObjectives The aim of this study is to develop a computer-aided diagnosis method to assist physicians in evaluating sacroiliac radiographs. Methods Convolutional neural networks, a deep learning method, were used in this retrospective study. Transfer learning was implemented with pre-trained VGG-16, ResNet-101 and Inception-v3 networks. Normal pelvic radiographs (n = 290) and pelvic radiographs with sacroiliitis (n = 295) were used for the training of networks. Results The training results were evaluated with the criteria of accuracy, sensitivity, specificity and precision calculated from the confusion matrix and AUC (area under the ROC curve) calculated from ROC (receiver operating characteristic) curve. Pre-trained VGG-16 model revealed accuracy, sensitivity, specificity, precision and AUC figures of 89.9%, 90.9%, 88.9%, 88.9% and 0.96 with test images, respectively. These results were 84.3%, 91.9%, 78.8%, 75.6 and 0.92 with pre-trained ResNet-101, and 82.0%, 79.6%, 85.0%, 86.7% and 0.90 with pre-trained inception-v3, respectively. Conclusions Successful results were obtained with all three models in this study where transfer learning was applied with pre-trained VGG-16, ResNet-101 and Inception-v3 networks. This method can assist clinicians in the diagnosis of sacroiliitis, provide them with a second objective interpretation and also reduce the need for advanced imaging methods such as magnetic resonance imaging.Article Citation - WoS: 8Citation - Scopus: 8Comparative Analysis on Wavelet-Based Detection of Finite Duration Low-Amplitude Signals Related To Ventricular Late Potentials(Iop Publishing Ltd, 2004) Mousa, A; Yilmaz, AVentricular late potentials (VLPs) are considered as a noninvasive marker of patients with myocardial infarction, who are prone to the development of ventricular tachycardia. This paper investigates the effects of variations in physical properties of myocardial infarcts in terms of their effects on the parametric variations in VLP analysis. A sufficiently large set of signals underlining the behavior of physical parameters was employed to represent the effect of physical size, position, orientation and type of infarct. The approximated signals are variations from real electrocardiography signals by adding potentials representing late potentials based on duration, frequency, amplitude and position. The aim is not to exactly model VLP but rather to generate an approximate set of signals to examine the performance of the standard methods for different possibilities in infarct dynamics. We investigate some of the detection approaches together with their related assumptions, and try to pinpoint the drawbacks and inaccuracies of these methods and also their assumptions. The three widely accepted criteria-QRS duration, root-mean-square and duration of the signal at the end of QRS for VLP detection-were used in the investigation. Results from the application of these parameters to the set of signals are presented. In addition we investigate the physical nature of an infarct and list a number of possible reasons that might be the cause of a low success rate for the detection of additive potentials. To improve the performance of the common methods, two more wavelet transform parameters are added to those of the standard methods. The method derived from this analysis is presented as an alternative means for the detection of late signals named as delayed potentials, a more general class that includes VLP as a subset.Article Citation - WoS: 14Citation - Scopus: 18A Validated Active Contour Method Driven by Parabolic Arc Model for Detection and Segmentation of Mitochondria(Academic Press inc Elsevier Science, 2016) Hassanpour, Reza Z.; Perkins, Guy; Tasel, Serdar F.; Mumcuoglu, Erkan U.Recent studies reveal that mitochondria take substantial responsibility in cellular functions that are closely related to aging diseases caused by degeneration of neurons. These studies emphasize that the membrane and crista morphology of a mitochondrion should receive attention in order to investigate the link between mitochondria] function and its physical structure. Electron microscope tomography (EMT) allows analysis of the inner structures of mitochondria by providing highly detailed visual data from large volumes. Computerized segmentation of mitochondria with minimum manual effort is essential to accelerate the study of mitochondrial structure/function relationships. In this work, we improved and extended our previous attempts to detect and segment mitochondria from transmission electron microcopy (TEM) images. A parabolic arc model was utilized to extract membrane structures. Then, curve energy based active contours were employed to obtain roughly outlined candidate mitochondrial regions. Finally, a validation process was applied to obtain the final segmentation data. 3D extension of the algorithm is also presented in this paper. Our method achieved an average F-score performance of 0.84. Average Dice Similarity Coefficient and boundary error were measured as 0.87 and 14 nm respectively. (C) 2016 Elsevier Inc. All rights reserved.Article Citation - WoS: 22Citation - Scopus: 21Functionalizing Graphene by Embedded Boron Clusters(Iop Publishing Ltd, 2008) Ozdogan, Cem; Kunstmann, Jens; Fehske, Holger; Quandt, AlexanderWe present a model system that might serve as a blueprint for the controlled layout of graphene based nanodevices. The systems consists of chains of B-7 clusters implanted in a graphene matrix, where the boron clusters are not directly connected. We show that the graphene matrix easily accepts these alternating B-7-C-6 chains and that the implanted boron components may dramatically modify the electronic properties of graphene based nanomaterials. This suggests a functionalization of graphene nanomaterials, where the semiconducting properties might be supplemented by parts of the graphene matrix itself, but the basic wiring will be provided by alternating chains of implanted boron clusters that connect these areas.Article Citation - WoS: 21Citation - Scopus: 22Computerized Detection and Segmentation of Mitochondria on Electron Microscope Images(Wiley, 2012) Tasel, S. F.; Perkins, G.; Martone, M. E.; Gurcan, M. N.; Mumcuoglu, E. U.; Hassanpour, R.Mitochondrial function plays an important role in the regulation of cellular life and death, including disease states. Disturbance in mitochondrial function and distribution can be accompanied by significant morphological alterations. Electron microscopy tomography (EMT) is a powerful technique to study the 3D structure of mitochondria, but the automatic detection and segmentation of mitochondria in EMT volumes has been challenging due to the presence of subcellular structures and imaging artifacts. Therefore, the interpretation, measurement and analysis of mitochondrial distribution and features have been time consuming, and development of specialized software tools is very important for high-throughput analyses needed to expedite the myriad studies on cellular events. Typically, mitochondrial EMT volumes are segmented manually using special software tools. Automatic contour extraction on large images with multiple mitochondria and many other subcellular structures is still an unaddressed problem. The purpose of this work is to develop computer algorithms to detect and segment both fully and partially seen mitochondria on electron microscopy images. The detection method relies on mitochondria's approximately elliptical shape and double membrane boundary. Initial detection results are first refined using active contours. Then, our seed point selection method automatically selects reliable seed points along the contour, and segmentation is finalized by automatically incorporating a live-wire graph search algorithm between these seed points. In our evaluations on four images containing multiple mitochondria, 52 ellipses are detected among which 42 are true and 10 are false detections. After false ellipses are eliminated manually, 14 out of 15 fully seen mitochondria and 4 out of 7 partially seen mitochondria are successfully detected. When compared with the segmentation of a trained reader, 91% Dice similarity coefficient was achieved with an average 4.9 nm boundary error.
