Comparative Performance Analysis of Filtering Methods for Removing Baseline Wander Noise From an Ecg Signal
Loading...

Date
2024
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
World Scientific Publ Co Pte Ltd
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
ECG signals play a vital role in the diagnosis of cardiovascular conditions. However, they often suffer from the effects of various noise sources, including baseline wandering, respiratory artifact noise, power line interference and electrode motion artifacts. To overcome these challenges, it is imperative to implement low-frequency signal noise reduction strategies. Such strategies aim to significantly improve the quality of ECG signals, thus promoting more accurate and reliable diagnosis of cardiovascular disorders. This paper conducts a comparative analysis to assess the effectiveness of commonly used filtering and wavelet techniques in reducing Baseline Wander (BW) noise within ECG signals generated by the influence of breathing or electrode movements. It is common to observe the selection and evaluation of only one particular technique in the existing literature. In contrast, this study aims to provide a comprehensive comparative analysis, providing insight into the performance and relative merits of different techniques. Our research uses both filtering and Discrete Wavelet Transform (DWT) techniques in baseline noise removal. In this context, a reference point is established utilizing noise-free signals and a meticulous investigation of the wavelet-based approach that most effectively eliminates the resulting noise is provided. Subsequently, we assess the reference input and output signal via Signal-to-Noise Ratio (SNR) and Kolmogorov-Smirnov statistical test measurements. The most important contribution of this work to the scientific community resides in the comprehensive examination of IIR/FIR-based and wavelet method-based filtering methods capable of yielding the highest SNR levels across various ECG signals with various types of BW noise. Additionally, the effectiveness of the Chebychev-II filter in BW noise removal is highlighted. Our study was conducted using the MATLAB platform and code command lines were shared to facilitate the reproduction of our study by other researchers. It is considered that this study will be an important reference in the selection of effective techniques for removing BW noise within ECG signals.
Description
Ahmad, Imteyaz/0000-0002-4258-4521
ORCID
Keywords
Baseline Wander, Breathing Noise, Noise Artifacts, Motion Artifacts
Fields of Science
0206 medical engineering, 02 engineering and technology, 0210 nano-technology
Citation
Özaydın, Selma; Ahmad, Imteyaz (2024). "Comparative Performance Analysis of Filtering Methods for Removing Baseline Wander Noise from an ECG Signal", Fluctuation and Noise Letters.
WoS Q
Q4
Scopus Q
Q2

OpenCitations Citation Count
1
Source
Fluctuation and Noise Letters
Volume
23
Issue
4
Start Page
End Page
PlumX Metrics
Citations
Scopus : 4
Captures
Mendeley Readers : 4
SCOPUS™ Citations
4
checked on Feb 26, 2026
Web of Science™ Citations
2
checked on Feb 26, 2026
Page Views
3
checked on Feb 26, 2026
Google Scholar™

OpenAlex FWCI
1.2914
Sustainable Development Goals
7
AFFORDABLE AND CLEAN ENERGY


