Abstract

In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 10(1)-10(5) cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.

Description

Tamer, Ugur/0000-0001-9989-6123; Suludere, Zekiye/0000-0002-1207-5814; Cetin, Demet/0000-0003-1186-4229; Yildirim, Ender/0000-0002-7969-2243

Keywords

E. Coil, Microfluidic Chip, Immunornagnetic Separation, Fluorescence, Sandwich Immunoassay, Immunoassay, Chitosan, Staining and Labeling, Enterobacter aerogenes, Microfluidic Analytical Techniques, Antibodies, Bacterial, Magnetics, Spectrometry, Fluorescence, Salmonella enteritidis, Lab-On-A-Chip Devices, Luminescent Measurements, Quantum Dots, Cadmium Compounds, Escherichia coli, Nanoparticles, Fluorometry, Tellurium

Fields of Science

02 engineering and technology, 01 natural sciences, 0104 chemical sciences, 0210 nano-technology

Citation

Kasap, Esin Nagihan...et al., "Fast fluorometric enumeration of E. coli using passive chip", Journal of Microbiological Methods, Vol. 164, (2019).

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
16

Source

Journal of Microbiological Methods

Volume

164

Issue

Start Page

105680

End Page

PlumX Metrics
Citations

CrossRef : 16

Scopus : 16

PubMed : 4

Captures

Mendeley Readers : 26

SCOPUS™ Citations

16

checked on Feb 25, 2026

Web of Science™ Citations

12

checked on Feb 25, 2026

Page Views

3

checked on Feb 25, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.2716

Sustainable Development Goals

SDG data is not available