Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Unbalanced Operation in Transformers Used in Pv Plants

dc.contributor.author Yukselen, Emir
dc.contributor.author Iskender, Ires
dc.date.accessioned 2024-05-14T07:49:35Z
dc.date.accessioned 2025-09-18T16:07:31Z
dc.date.available 2024-05-14T07:49:35Z
dc.date.available 2025-09-18T16:07:31Z
dc.date.issued 2022
dc.description.abstract energy has become the most preferred energy sources today due to its environmental and economic advantages. One of the renewable energies is solar energy, in which Photovoltaic (PV) cells are used to convert solar energy into electrical energy. In this respect, Solar Power Plant (SPP) is one of the popular renewable energy sources and the integration of such power sources into electricity grids has been increasing in recent years. Transformers are one of the largest capital investments in solar power generation and the way they work is different from transformers used in a substation. Therefore, failure of transformers has significant economic effects on electrical networks. The PV type transformer is powered by the inverter and needs to be customized to work with every system. Consequently, the safe operation and reliability of this type of transformer is critical to the sustainability of the electrical grid. Consequently, identifying the probability of failure as a preventative action for grid protection is critical and should be addressed to improve electrical system reliability. The main purpose of this study is to analyze the effects of the unbalanced operation of the inverter on the performance of the special type transformer used in the PV plant and to show how the inverter operation can affect the operation of the transformer. en_US
dc.description.sponsorship SEM Transformatoer Inc.; Elektro Trans Ar-Ge. Mueh. Tek. Dan. Elektronik Yaz. Taa. San. Tic. Ltd. Sti. en_US
dc.description.sponsorship The author would like to thank SEM Transformatoer Inc. and Elektro Trans Ar-Ge. Mueh. Tek. Dan. Elektronik Yaz. Taa. San. Tic. Ltd. Sti. for providing all the necessary supports. en_US
dc.identifier.citation Yükselen, Emir; Iskender, Ires (2022). "Unbalanced Operation in Transformers Used in PV Plants", International Journal of Renewable Energy Research, Vol.12, No.4, pp.2200-2205. en_US
dc.identifier.doi 10.20508/ijrer.v12i4.13596.g8586
dc.identifier.issn 1309-0127
dc.identifier.scopus 2-s2.0-85144822807
dc.identifier.uri https://doi.org/10.20508/ijrer.v12i4.13596.g8586
dc.identifier.uri https://hdl.handle.net/20.500.12416/14773
dc.language.iso en en_US
dc.publisher int Journal Renewable Energy Research en_US
dc.relation.ispartof International Journal of Renewable Energy Research en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Photovoltaic (Pv) en_US
dc.subject Solar Power Plant (Spp) en_US
dc.subject Transformer en_US
dc.subject Finite Element Method (Fem) en_US
dc.subject Unbalance Condition en_US
dc.title Unbalanced Operation in Transformers Used in Pv Plants en_US
dc.title Unbalanced Operation in Transformers Used in PV Plants tr_TR
dc.type Article en_US
dspace.entity.type Publication
gdc.author.scopusid 57715481400
gdc.author.scopusid 15019302900
gdc.author.wosid Iskender, Ires/Aak-8084-2020
gdc.author.wosid Yukselen, Emir/Kib-2167-2024
gdc.author.yokid 133746
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department Çankaya University en_US
gdc.description.departmenttemp [Yukselen, Emir] Gazi Univ, Elect & Elect Engn Dept, Ankara, Turkey; [Yukselen, Emir] SEM Transformator Inc, Elect Design Dept, Ankara, Turkey; [Iskender, Ires] Cankaya Univ, Elect Elect Engn Dept, Ankara, Turkey en_US
gdc.description.endpage 2205 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 2200 en_US
gdc.description.volume 12 en_US
gdc.description.woscitationindex Emerging Sources Citation Index
gdc.description.wosquality Q4
gdc.identifier.openalex W4312436352
gdc.identifier.wos WOS:000905144200021
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.accesstype GOLD
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0.0
gdc.oaire.influence 2.4895952E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 1.7808596E-9
gdc.oaire.publicfunded false
gdc.openalex.fwci 0.11695378
gdc.openalex.normalizedpercentile 0.32
gdc.opencitations.count 0
gdc.plumx.mendeley 3
gdc.plumx.scopuscites 2
gdc.publishedmonth 12
gdc.scopus.citedcount 2
gdc.virtual.author İskender, İres
gdc.wos.citedcount 1
relation.isAuthorOfPublication 2219cbd5-9b30-48e0-b360-4bc56c99320f
relation.isAuthorOfPublication.latestForDiscovery 2219cbd5-9b30-48e0-b360-4bc56c99320f
relation.isOrgUnitOfPublication a8b0a996-7c01-41a1-85be-843ba585ef45
relation.isOrgUnitOfPublication 43797d4e-4177-4b74-bd9b-38623b8aeefa
relation.isOrgUnitOfPublication 0b9123e4-4136-493b-9ffd-be856af2cdb1
relation.isOrgUnitOfPublication.latestForDiscovery a8b0a996-7c01-41a1-85be-843ba585ef45

Files