Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Experimental Investigation of Damaged Square Short Rc Columns With Low Slenderness Retrofitted by Cfrp Strips Under Axial Load

Loading...
Publication Logo

Date

2020

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Science inc

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

The aim of this study is to develop the retrofitting details, which will increase axial ultimate load capacity, stiffness, displacement ductility ratios, and energy dissipation capacities of short reinforced concrete (RC) low slenderness columns to avoid adverse effects on earthquake performance. The main variables examined in the experimental study are the Carbon Reinforced Fiber Polymer (CFRP) strip width used for retrofitting, the distance between CFRP strips, the use of the anchor at the overlap zone in the CFRP strips, and the placement of the CFRP strips horizontally or vertically to the column axis. For these purposes, eleven square short RC columns with a dimension of 150x150x500 mm (with low slenderness ratio: lambda = 11.5) were produced. The columns were damaged up to 50% of their axial load carrying capacity, then retrofitted with CFRP strips in different ways. The short RC columns with low slenderness ratio were tested under monotonic axial loading until they failure. By obtaining the axial load-displacement graphs of the test specimens, the ultimate axial load capacity, initial stiffness value, displacement-ductility ratios, and energy dissipation capacities are calculated and interpreted. It has been found that the most successful retrofitting detail is obtained when CFRP strips are placed perpendicular to the column axis, and CFRP fan-type anchors are used in the strip overlap region.

Description

Mercimek, Omer/0000-0002-5367-6077; Ozdemir, Anil/0000-0001-6563-5144

Keywords

Rc Short Column, Cfrp, Retrofitting, Axial Load, Ductility And Energy Dissipation

Fields of Science

02 engineering and technology, 0201 civil engineering

Citation

Ghoroubi, Rahim...at all (2020). "Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load", Structures, Vol. 28, pp. 170-180.

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
23

Source

Structures

Volume

28

Issue

Start Page

170

End Page

180
PlumX Metrics
Citations

CrossRef : 23

Scopus : 19

Captures

Mendeley Readers : 16

SCOPUS™ Citations

20

checked on Feb 23, 2026

Web of Science™ Citations

21

checked on Feb 23, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.10611573

Sustainable Development Goals

11

SUSTAINABLE CITIES AND COMMUNITIES
SUSTAINABLE CITIES AND COMMUNITIES Logo