Numerical Study on Effects of Computational Domain Length on Flow Field in Standing Wave Thermoacoustic Couple

Loading...
Publication Logo

Date

2019

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Sci Ltd

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

For the analysis of thermoacoustic (TA) devices, computational methods are commonly used. In the computational studies found in the literature, the flow domain has been modelled differently by different researchers. A common approach in modelling the flow domain is to truncate the computational domain around the stack, instead of modelling the whole resonator to save computational time. However, where to truncate the domain is not clear. In this study, we have investigated how the simulation results are affected by the computational domain length (I-d) when the truncated domain approach is used. For this purpose, a standing wave TA couple which undergoes a refrigeration cycle was considered. The stack plate thickness was assumed to be zero and the simulations were performed for six different dimensionless domain length (I-d/lambda) varying between 0.029 and 0.180. Frequency and Mach number were taken as 100 Hz and 0.01, respectively, and kept constant for all the cases considered. The mean pressure and the pressure amplitude were taken as 10 kPa and 170 Pa, respectively (Drive ratio of 1.7%). Helium was considered as the working fluid. To assess the accuracy of the simulation results, the pressure distributions across the domain were compared with that of the standing wave. In addition to the pressure variation, the effects of the domain length on the phase delay of the pressure and velocity waves along the stack plate were also investigated. The results showed that with the increasing I-d/lambda. ratio, the simulated pressure distribution compares better with the standing wave pressure distribution. With the lowest I-d/lambda ratio (0.029) considered, the difference between the amplitudes of the computed pressure distribution and theoretical standing wave pressure distribution was approximately 50 Pa. However, as I-d/lambda value increases, the simulation results approach to the theoretical standing wave pressure distribution better. The computational results obtained with Id/lambda = 0.132 and 0.180, were almost identical with standing wave acoustic field. Hence, it was concluded that the domain length has a significant effect on the accuracy of the computational results when the truncated domain approach is used. It was also observed that for a given TA device and operating parameters, there is a minimum I-d/lambda value for obtaining reliable results.

Description

Yildirim, Ender/0000-0002-7969-2243

Keywords

Standing Wave, Thermoacoustic, Refrigerator

Fields of Science

0211 other engineering and technologies, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology

Citation

Mergen, Suhan; Yildirim, Ender; Turkoglu, Hasmet, "Numerical study on effects of computational domain length on flow field in standing wave thermoacoustic couple", Cryogenics, Vol. 98, pp. 139-147, (2019).

WoS Q

Q2

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
12

Source

Cryogenics

Volume

98

Issue

Start Page

139

End Page

147
PlumX Metrics
Citations

CrossRef : 12

Scopus : 13

Captures

Mendeley Readers : 18

SCOPUS™ Citations

14

checked on Feb 24, 2026

Web of Science™ Citations

11

checked on Feb 24, 2026

Page Views

1

checked on Feb 24, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.88662269

Sustainable Development Goals

SDG data is not available