PubMed İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12416/8650
Browse
Browsing PubMed İndeksli Yayınlar Koleksiyonu by Scopus Q "Q3"
Now showing 1 - 20 of 104
- Results Per Page
- Sort Options
Article Citation - WoS: 10Citation - Scopus: 13Adaptive Optics Corrections of Scintillations of Hermite-Gaussian Modes in an Oceanic Medium(Optical Soc Amer, 2020) Baykal, YahyaAdaptive optics correction of the scintillation index is found when Hermite-Gaussian laser beams are used in oceanic turbulence. Adaptive optics filter functions are used to find how the tilt, focus, astigmatism, coma, and total correction will behave under high order mode excitation. Reduction of the oceanic scintillation under various oceanic turbulence and system parameters is examined under different high order modes. Also, the effects of the source size, wavelength, and link length on the total adaptive optics correction of Hermite-Gaussian modes in an oceanic medium are investigated for different modes. (C) 2020 Optical Society of AmericaArticle Citation - WoS: 2Citation - Scopus: 2Age-Related Decline in Source and Associative Memory(Springer Heidelberg, 2025) Sumer, Erdi; Kaynak, HandeThis review explores the multifaceted nature of age-related decline in source memory and associative memory. The review highlights the potential effects of age-related decline in these types of memory. By integrating insights from behavioral, cognitive, and neuroscientific research, it examines how encoding, retrieval, and neural mechanisms influence this decline. Understanding these processes is critical to alleviate memory decline in older adults. Directing attention to source information during encoding, employing unitization techniques to strengthen memory associations, and utilizing metacognitive strategies to focus on relevant details show promise in enhancing memory retrieval for older adults. However, the review acknowledges limitations in processing resources and executive function, necessitating a nuanced approach to the complexities of age-related decline. In conclusion, this review underscores the importance of understanding the complexities of age-related source and associative memory decline and the potential benefits of specific cognitive strategies. It emphasizes the need for continued research on age-related memory function to improve the quality of life for aging populations.Article Citation - WoS: 22Citation - Scopus: 23Alternative Interpretation of the Edge-Diffraction Phenomenon(Optical Soc Amer, 2008) Umul, Yusuf Z.An alternative interpretation of the phenomenon of edge diffraction is proposed according to a new separation of the Fresnel function. The subfields are investigated in the problem of diffraction of a plane wave by a perfectly conducting half-plane, and the results are compared numerically with other interpretations. (c) 2008 Optical Society of America.Article Citation - WoS: 37Citation - Scopus: 44Annular Beam Scintillations in Strong Turbulence(Optical Soc Amer, 2010) Gercekcioglu, Hamza; Baykal, Yahya; Nakiboglu, CemA scintillation index formulation for annular beams in strong turbulence is developed that is also valid in moderate and weak turbulence. In our derivation, a modified Rytov solution is employed to obtain the small-scale and large-scale scintillation indices of annular beams by utilizing the amplitude spatial filtering of the atmospheric spectrum. Our solution yields only the on-axis scintillation index for the annular beam and correctly reduces to the existing strong turbulence results for the Gaussian beam-thus plane and spherical wave scintillation indices-and also correctly yields the existing weak turbulence annular beam scintillations. Compared to collimated Gaussian beam, plane, and spherical wave scintillations, collimated annular beams seem to be advantageous in the weak regime but lose this advantage in strongly turbulent atmosphere. It is observed that the contribution of annular beam scintillations comes mainly from the small-scale effects. At a fixed primary beam size, the scintillations of thinner collimated annular beams compared to thicker collimated annular beams are smaller in moderate turbulence but larger in strong turbulence; however, thinner annular beams of finite focal length have a smaller scintillation index than the thicker annular beams in strong turbulence. Decrease in the focal length decreases the annular beam scintillations in strong turbulence. Examining constant area annular beams, smaller primary sized annular structures have larger scintillations in moderate but smaller scintillations in strong turbulence. (C) 2010 Optical Society of AmericaArticle Citation - WoS: 391Citation - Scopus: 431Anomalous Diffusion Expressed Through Fractional Order Differential Operators in the Bloch-Torrey Equation(Academic Press inc Elsevier Science, 2008) Abdullah, Osama; Baleanu, Dumitru; Zhou, Xiaohong Joe; Magin, Richard L.Diffusion weighted MRI is used clinically to detect and characterize neurodegenerative, malignant and ischemic diseases. The correlation between developing pathology and localized diffusion relies on d iffusi on -weighted pulse sequences to probe biophysical models of molecular diffusion-typically exp[-(bD)]-where D is the apparent diffusion coefficient (turn (2)/s) and b depends on the specific gradient pulse sequence parameters. Several recent studies have investigated the so-called anomalous diffusion stretched exponential model-exp[-(bD)(alpha)], where alpha is a measure of tissue complexity that can be derived from fractal models of tissue structure. In this paper we propose an alternative derivation for the stretched exponential model using fractional order space and time derivatives. First, we consider the case where the spatial Laplacian in the Bloch-Torrey equation is generalized to incorporate a fractional order Brownian model of diffusivity. Second, we consider the case where the time derivative in the Bloch-Torrey equation is replaced by a Riemann-Liouville fractional order time derivative expressed in the Caputo form. Both cases revert to the classical results for integer order operations. Fractional order dynamics derived for the first case were observed to fit the signal attenuation in diffusion-weighted images obtained from Sephadex gels, human articular cartilage and human brain. Future developments of this approach may be useful for classifying anomalous diffusion in tissues with developing pathology. (c) 2007 Elsevier Inc. All rights reserved.Article Citation - WoS: 27Citation - Scopus: 26Aperture Averaging in Multiple-Input Single-Output Free-Space Optical Systems Using Partially Coherent Radial Array Beams(Optical Soc Amer, 2016) Baykal, Yahya; Uysal, Murat; Gokce, Muhsin CanerMultiple-input single-output (MISO) techniques are employed in free-space optical (FSO) links to mitigate the degrading effects of atmospheric turbulence. In this paper, for the MISO FSO system, a partially coherent radial array and a finite-sized receiver aperture are used at the transmitter and the receiver, respectively. Using the extended Huygens - Fresnel principle, we formulate the average power and the power correlation at the finite-sized slow detector in weak atmospheric turbulence. System performance indicators such as the power scintillation index and the aperture averaging factor are determined. Effects of the source size, ring radius, receiver aperture radius, link distance, and structure constant and the degree of source coherence are analyzed on the performance of the MISO FSO system. In the limiting cases, the numerical results are found to be the same when compared to the existing coherent and partially coherent Gaussian beam scintillation indices. (C) 2016 Optical Society of AmericaArticle Citation - WoS: 7Citation - Scopus: 8Apertured Paraxial Bessel Beams(Optical Soc Amer, 2010) Umul, Yusuf Z.The paraxial Bessel beam is obtained by applying an approximation in the wavenumbers. The scattering of the beams by a circular aperture in an absorbing screen is investigated. The scattered fields are expressed in terms of the Fresnel integrals by evaluating the Kirchhoff diffraction integral in the paraxial approximation. The results are examined numerically. (C) 2010 Optical Society of AmericaArticle Citation - WoS: 127Citation - Scopus: 135Average Intensity and Spreading of Cosh-Gaussian Laser Beams in the Turbulent Atmosphere(Optical Soc Amer, 2005) Eyyuboglu, HT; Baykal, YThe average intensity and spreading of cosh-Gaussian laser beams in the turbulent atmosphere are examined. Our research is based principally on formulating the average-intensity profile at the receiver plane for cosh-Gaussian excitation. The limiting cases of our formulation for the average intensity are found to reduce correctly to the existing Gaussian beam wave result in turbulence and the cosh-Gaussian beam result in free space (in the absence of turbulence). The average intensity and the broadening of the cosh-Gaussian beam wave after it propagates in the turbulent atmosphere are numerically evaluated versus source size, beam displacement, link length, structure constant, and two wavelengths of 0.85 and 1.55 mum, which are most widely used in currently employed free-space-optical links. Results indicate that in turbulence the beam is widened beyond its free-space diffraction values. At the receiver plane, analogous to the case of free space, this diffraction eventually leads to transformation of the cosh-Gaussian beam into an oscillatory average-intensity profile with a Gaussian envelope. (C) 2005 Optical Society of America.Article Citation - WoS: 4Citation - Scopus: 4Beam Diffraction by a Resistive Half-Plane(Optical Soc Amer, 2015) Umul, Yusuf ZiyaThe scattering of a Gaussian beam by a resistive half-screen is investigated. Far-field approximation is used in evaluation of geometrical optics and diffracted waves. The uniform expression of the diffracted waves by the resistive half-plane, which was found with the Sommerfeld-Maliuzhinets method, is obtained. The scattered fields for the case of the beam incidence are evaluated with the technique of a complex point source. The resultant wave expressions are examined numerically. (C) 2015 Optical Society of AmericaArticle Citation - WoS: 11Citation - Scopus: 12Bit Error Rate Analysis of Gaussian, Annular Gaussian, Cos Gaussian, and Cosh Gaussian Beams With the Help of Random Phase Screens(Optical Soc Amer, 2014) Eyyuboglu, Halil T.Using the random phase screen approach, we carry out a simulation analysis of the probability of error performance of Gaussian, annular Gaussian, cos Gaussian, and cosh Gaussian beams. In our scenario, these beams are intensity-modulated by the randomly generated binary symbols of an electrical message signal and then launched from the transmitter plane in equal powers. They propagate through a turbulent atmosphere modeled by a series of random phase screens. Upon arriving at the receiver plane, detection is performed in a circuitry consisting of a pin photodiode and a matched filter. The symbols detected are compared with the transmitted ones, errors are counted, and from there the probability of error is evaluated numerically. Within the range of source and propagation parameters tested, the lowest probability of error is obtained for the annular Gaussian beam. Our investigation reveals that there is hardly any difference between the aperture-averaged scintillations of the beams used, and the distinctive advantage of the annular Gaussian beam lies in the fact that the receiver aperture captures the maximum amount of power when this particular beam is launched from the transmitter plane. (C) 2014 Optical Society of AmericaArticle Citation - WoS: 30Citation - Scopus: 31Bit Error Rate of Pulse Position Modulated Optical Wireless Communication Links in Oceanic Turbulence(Optical Soc Amer, 2018) Baykal, YahyaThe upper bound of the average bit error rate (BER) of a pulse position modulated (PPM) optical wireless communication (OWC) link operating in oceanic turbulence is formulated. BER variations against the changes in the ratio of temperature to salinity contributions to the refractive index spectrum, the rate of dissipation of mean-squared temperature, and the rate of dissipation of kinetic energy per unit mass of fluid are found at various data bit rates, average current gains of the avalanche photodiode (APD), and M values of the M-ary PPM. It is found that under any oceanic turbulence parameters, BER performance of the PPM OWC system becomes favorable at smaller data bit rates, M values, and at larger average current gains of APD. (c) 2018 Optical Society of AmericaArticle Citation - WoS: 28Citation - Scopus: 28Bit Error Rates for General Beams(Optical Soc Amer, 2008) Arpali, Serap Altay; Eyyuboglu, Halil T.; Baykal, YahyaIn order to analyze the effect of beam type on free space optical communication systems, bit error rate (BER) values versus signal-to-noise ratio (SNR) are calculated for zero order and higher order general beam types, namely for Gaussian, cos-Gaussian, cosh-Gaussian, and annular beams. BER analysis is based on optical scintillation using log-normal distribution for the intensity, which is valid in weak atmospheric turbulence. BERs for these beams are plotted under variations of propagation length, source size, wavelength of operation, and order of the beam. According to our graphical outputs, at small source sizes and long propagation distances, the smallest BER value is obtained for the annular beam. On the other hand, at large source size and small propagation distance, the smallest BER value is obtained for the cos-Gaussian beam, Moreover, our study of the order of the beam shows that higher order beams have lower BER values than the zero order beams at longer propagation distances. But this drop compared with the order seems to be incremental. (c) 2008 Optical Society of AmericaArticle Citation - WoS: 31Citation - Scopus: 40Chemometric Determination of Naproxen Sodium and Pseudoephedrine Hydrochloride in Tablets by Hplc(Pharmaceutical Soc Japan, 2006) Özdemir, A; Aksoy, H; Üstündag, Ö; Baleanu, D; Dinç, EA new chemometric determination by high-performance liquid chromatography (HPLC) with photodiode array (PDA) detection was implemented for the simultaneous determination of naproxen sodium and pseudoephedrine hydrochloride in tablets. Three chemometric calibration techniques, classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS) were applied to the peak area at multiwavelength PDA detector responses. The combinations of HPLC with chernometric calibration techniques were called HPLC-CLS, HPLC-PCR and HPLC-PLS. For comparison purposes the HPLC method called the classic HPLC method was used to confirm the results obtained from combined HPLC-chemometric calibration techniques. A good chromatographic separation between two drugs with losartan potassium as an internal standard was achieved using a Waters Symmetry (R) C18 Column 5 mu m 4.6 +/- 250 mm and a mobile phase containing 0.2 m acetate buffer and acetonitrile (v/v, 40 : 60). The multiwavelength PDA detection was measured at five different wavelengths. The chromatograms were recorded as a training set in the mobile phase. Three HPLC-chemometric calibrations and the classic-HPLC method were used to test the synthetic mixtures of naproxen sodium and pseudoephedrine hydrochloride in the presence of the internal standard. The HPLC-chemometric approaches were applied to real samples containing drugs of interest. The experimental results obtained from HPLC-chemometric calibrations were compared with those obtained by a classic HPLC method.Article Citation - WoS: 16Citation - Scopus: 16Comparative Application of Wavelet Approaches To Absorption and Ratio Spectra for the Simultaneous Determination of Diminazene Aceturate and Phenazone in Veterinary Granules for Injection(Govi-verlag Pharmazeutischer verlag Gmbh, 2005) Dinç, E; Baleanu, Dumitru; Kanbur, M; Baleanu, D; MatematikA comparison of two wavelet approaches, Daubechies and reverse Biorthogonal, is described for the quantitative resolution of a binary mixture of diminazene aceturate (DIMA) and phenazone (PHE) in veterinary granules for injection without any chemical separation. These two approaches were specified as db4 (a = 180) and rbior3.7 (a = 125) respectively, after testing the signal analysis parameters for the overlapping absorption spectra and ratio spectra. In the first step db4 (a = 180) was applied to the original absorbance data vector of DIMA and PHE. In the second step rbio3.7 (a = 125) was applied to the ratio spectra data vectors of DIMA using the divisor PHE. The same approach was also subjected to the ratio spectra of PHE using the divisor DIMA. The db4 (a = 180) and rbior3.7 (a = 125) calibration graphs were constructed using the transformation values obtained in the wavelet domain. In the method validation, the wavelet calibration functions were tested using synthetic mixtures and the standard addition technique. The simultaneous quantitative analysis of DIMA and PHE in the commercial veterinary preparation was achieved by the elaborated methods. The assay results were compared with each other and good agreement was observed.Article Citation - WoS: 4Citation - Scopus: 3A Comparison of Crystal Phenol Treatment, Midline Primary Closure and Limberg Flap Reconstruction Methods in Female Patients With Primary Pilonidal Sinus Disease(Edizioni Luigi Pozzi, 2021) Kanlioz, Murat; Uyanikoglu, Hacer; Ekici, Ugur; Karatas, Turgay; Tatli, FaikPilonidal sinus disease (PSD) is a chronic problem often occurs in healthy hirsute men, however, women may also be affected. A range of conservative techniques to surgical flaps have been used to treat this condition. Currently, midline primary closure (MPC) is considered the standard of therapy; however, no statistically significant difference has been noted between primary versus secondary (Karydakis flap or Limberg flap) closure. Recently, flap reconstruction methods have been applied and superiority of these methods have been shown. Treatment methods should be employed to the individual, taking into account recurrence and complication rates of the method, recovery time, patients' preference and surgeon's skill.Article Citation - WoS: 64Citation - Scopus: 70Complex Degree of Coherence for Partially Coherent General Beams in Atmospheric Turbulence(Optical Soc Amer, 2007) Eyyuboglu, Halil T.; Baykal, Yahya; Cai, YangjianWith the use of the general beam formulation, the modulus of the complex degree of coherence for partially coherent cosh-Gaussian, cos-Gaussian, Gaussian, annular and higher-order Gaussian optical beams is evaluated in atmospheric turbulence. For different propagation lengths in horizontal atmospheric links, the moduli of the complex degree of coherence at the source and receiver planes are examined when reference points are taken on the receiver axis and off-axis. In the on-axis case, it is observed that in propagation, the moduli of the complex degree of coherence are symmetrical and look like the intensity profile of the related coherent beam propagating in a turbulent atmosphere. For all the beams considered, the moduli of the complex degree of coherence profiles turn into Gaussian shapes beyond certain propagation lengths. In the off-axis case, the moduli of complex degree of coherence patterns become drifted at the earlier propagation lengths. Among the beams investigated, the cos-Gaussian beam is found to be almost independent of the changes in the source partial coherence parameter, and the annular beam seems to be affected the most against the variations of the source partial coherence parameter. (c) 2007 Optical Society of America.Article Citation - WoS: 13Citation - Scopus: 14Continuous Wavelet Transformation Applied To the Simultaneous Quantitative Analysis of Two-Component Mixtures(Govi-verlag Pharmazeutischer verlag Gmbh, 2004) Dinç, E; Baleanu, Dumitru; Baleanu, D; Üstündag, Ö; Aboul-Enein, HY; MatematikIn this paper we developed a graphical method based on Haar (HA) and Mexican (MEX) one-dimensional continuous wavelet transforms and we applied it to a mixture of hydrochlorothiazide (HCT) and spironolactone (SP) in the presence of strongly overlapping signals. Keeping in mind to obtain an appropriately transformed spectrum, we tested several values of the scaling parameter a and the point number of the analysed spectrum in the concentration range of 2-22 mug/ml for both active compounds. The optimal values of the scale parameters and the corresponding frequencies were found to be a = 32 and 0.031 for HA and a = 30 and 0.008 for MEX corresponding to 400 points. HA and MEX methods based on a zero crossing technique were applied to the analysed signal and their regression lines at the selected points were obtained. The validation of the above methods was carried out by analysing different synthetic mixtures containing HCT and SP. MATLAB 6.5. Software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were briefly explained. The method developed in this paper is rapid, easy to apply, inexpensive and is suitable for analysing the overlapping signals of compounds in their mixtures without any chemical pre-treatment.Article Citation - WoS: 88Citation - Scopus: 87Correlation and Structure Functions of Hermite-Sinusoidal Laser Beams in a Turbulent Atmosphere(Optical Soc Amer, 2004) Baykal, YTo study the performance of atmospheric optical links by using Hermite-sinusoidal-Gaussian laser beam sources, we derive the log-amplitude and the phase correlation and structure functions of such beams in a turbulent atmosphere. Our formulations correctly reduce to the known higher-order mode correlation and structure functions, which in turn reduce to the fundamental-mode (TEM00-mode) results. Several special cases of our formulation are presented, among which the case involving Hermite-cosh-Gaussian dependence is especially noted, since this case is of interest to us owing to the nature of cosh dependence exhibiting the concentration of the energy in the outer lobes of the beam. (C) 2004 Optical Society of America.Article Citation - WoS: 6Citation - Scopus: 6Correlation of Multimode Fields in Atmospheric Turbulence(Optica Publishing Group, 2023) Gokce, Muhsin Caner; Ata, Yalcin; Gercekcioglu, Hamza; Baykal, YahyaMultimode field correlations are evaluated in atmospheric turbulence. High order field correlations are special cases of the results that we obtained in this paper. Field correlations are presented for various numbers of mul- timodes, various multimode contents of the same number of modes, and various high order modes versus the diagonal distance from various receiver points, source size, link length, structure constant, and the wavelength. Our results will be of help especially in the design of heterodyne systems operating in turbulent atmosphere and fiber coupling efficiency in systems employing multimode excitation.(c) 2023 Optica Publishing GroupArticle Citation - WoS: 3Citation - Scopus: 2Correlations of Multimode Optical Incidences in a Turbulent Biological Tissue(Optica Publishing Group, 2023) Gokce, Muhsin Caner; Gerekcioglu, Hamza; Ata, Yalin; Baykal, YahyaIn a turbulent biological tissue, field correlations at the observation plane are found when a multimode optical incidence is used. For different multimode structures, variations of the multimode field correlations are evaluated against the biological tissue turbulence parameters, i.e., the strength coefficient of the refractive-index fluctuations, fractal dimension, characteristic length of heterogeneity, and the small length-scale factor. Using a chosen multimode content, for specific biological tissue types of liver parenchyma (mouse), intestinal epithelium (mouse), upper dermis (human), and deep dermis (mouse), field correlations are evaluated versus the strength coefficient of the refractive-index fluctuations and small length-scale factor. Again, with a chosen multimode content, behavior of the field correlations is studied against the strength coefficient of the refractive-index fluctuations for various diagonal lengths and the transverse coordinate at the observation plane. Finally, the field correlation versus the strength coefficient of the refractive-index fluctuations is reported for different single modes, which are special cases of multimode excitation. This topic is being reported in the literature for the first time, to our knowledge, and the presented results can be employed in many important biological tissue applications. (c) 2023 Optica Publishing

